Key points
- Solar power meters are built and calibrated for broad-spectrum sunlight, not for narrow red and near-infrared LED bands.
- One manufacturer reports that a solar meter read roughly 2 to 2.5 times higher than a lab spectroradiometer on the same panel.
- An irradiance number is only comparable if it states the distance, the instrument and who measured it.
- If your number came from a solar meter, the time you need for a given dose may be about twice as long as it looks.
The problem
To work out a session, you need the irradiance at your distance (see how dose works). Most brands publish it. Few say how they measured it, and there is no single standard that every consumer brand follows. Two panels that both claim "100 mW/cm² at 6 inches" may not be delivering the same light.
Why solar meters misread LEDs
Inexpensive solar power meters are designed to measure sunlight, which spreads its energy across a wide band of wavelengths. Their sensor does not respond equally to every wavelength, and the meter's calibration assumes the light it sees has the spectrum of the sun. A red light panel concentrates its output in two narrow bands, typically around 630–660 nm and 810–850 nm. When the light does not match the spectrum the meter was calibrated for, the reading is biased.
A spectroradiometer measures intensity wavelength by wavelength, so it can report only the light inside the bands that matter. It is the instrument accredited labs use, and it costs far more than a handheld solar meter.
How big is the error?
Independent, peer-reviewed comparisons for consumer panels are scarce. The clearest public figure comes from a manufacturer: Mito Red Light, which publishes test reports from an ISO/IEC 17025-accredited lab, states that a solar meter can read roughly 2 to 2.5 times higher than a spectroradiometer on the same panel, and suggests multiplying a solar reading by about 0.40 to 0.45 as a rough estimate.
What a trustworthy irradiance claim includes
- The distance, for example "at 6 in (15 cm)". Without it, the number means nothing.
- The instrument: spectroradiometer, thermal power sensor or solar meter.
- Who measured it, and whether that lab is accredited.
- A chart at several distances, so you can see how output falls off as you step back.
- A date, because models change.
Our rule
We only publish an irradiance figure with its distance and its source. We have not yet measured devices ourselves. Until we do, every figure on Vermeil Lab is labeled as the manufacturer’s, along with the instrument they say they used, or "instrument not stated".
Ready to run the numbers? Use the distance & dose calculator, and tick the solar meter box if that is where your figure came from.
Sources
- Mito Red Light. Independent test data (ISO/IEC 17025-accredited lab), updated April 2026. Manufacturer source.
- Iovine J. Why you shouldn’t use solar power meters for red light therapy devices. Opinion article.